Century 21 Macintyre Inc. 1692 Route 105 (819)4592355 (Office)
Description:
Don't let the fool you. Joseph is as comfortable speaking in French as he is in English. Joseph grewname up in the Glebe neighbourhood of Ottawa on the corner of Fourth and Bronson in a French Canadian family. The third in a family of four kids, he discovered the Gatineau Hills, north of Ottawa, as he took up skiing in the 1960's. This led him to move to Chelsea were he and his wife Marylies raised two children and have been residents there ever since. Joseph's outgoing personality has brought him in contact with many prospective buyers and sellers over the years and this as well as his business experience and his intimate knowledge of the area serve him well as he works with you in realising your Real Estate objectives.
Joseph P. Woods - Hammondsport NY Eswara V. Vallabhaneni - Elmira NY Winand H. A. M. Friederichs - Bath NY Mary E. Fortuna - Canisteo NY Karl Baker - New York NY
Assignee:
Koninklijke Philips Electronics N.V. - Eindhoven
International Classification:
H01K 118
US Classification:
313625, 313626, 313578
Abstract:
A hard-glass halogen gas-filled incandescent capsule with a single-end or a double-end has a tungsten filament with a primary coil extending from the barrel into the legs, and a secondary coil forming the barrel. One of the legs of the tungsten filament of the single-ended capsule extends into a pinch or press seal of the glass envelope to result in passive extinction of the electric arc at end-of-life. The end of the filament leg near the press seal may be connected to and/or supported by a molybdenum lead wire of the capsule that is within the pinch or the press seal via a clamp formed on the molybdenum lead wire. The passive extinction occurs when the electric arc is conducted through the filament extending into the press seal. Reliable extinction of the arc within the capsule is achieved with simplicity in construction and minimal materials. The primary coil is preferably stretched out to assume the diameter of the tungsten wire where it is embedded in a pinch seal.
Looped Frame Arc Tube Mounting Assembly For Metal Halide Lamp
Joseph Woods - Hammondsport NY, US John Bailey - Bradford NY, US Joseph Carbone - Hornell NY, US
Assignee:
KONINKLIJKE PHILIPS ELECTRONICS, N.V. - EINDHOVEN
International Classification:
H01J 17/18
US Classification:
313625
Abstract:
An arc tube mounting assembly () for a metal halide arc lamp () includes frame members () for supporting an arc tube (). The arc tube () is supported from above by a looped frame member () having a loop (A) which extends along opposing sides, and across top and base ends (A, B) of the arc tube (), thus evenly distributing the current to discharge electrode thereby cancelling magnetic forces which could displace the arc from the center of the arc tube (), resulting in improved lumen maintenance and extended life. A centering circle (B) of the frame member () wraps around the lower ceramic end plug (), providing coaxial alignment of the arc tube () and the tubular outer envelope ().
Compact Hid Arc Lamp Having Shrouded Arc Tube And Helical Lead Wire
Joseph P. Woods - Hammondsport NY, US John S. Bailey - Bradford NY, US Joseph J. Carbone - Hornell NY, US William T. Solsky - Bath NY, US Junming Tu - Bath NY, US
Assignee:
KONINKLIJKE PHILIPS ELECTRONICS N.V. - EINDHOVEN
International Classification:
H01J 61/36
US Classification:
313623
Abstract:
A compact open-rated HID lamp () having a shrouded arc tube () positioned within a compact outer envelope (), which lamp () has an arc tube mounting assembly () characterized by a long lead wire () which extends from the press seal () at the base end (A) of the outer envelope (), winds helically around the shroud () and extends into and is biased outwardly against the distal end (B) of the outer envelope (), thus not only conducting current to the distal electrode () of the arc tube (), but also centering and supporting the retaining shroud () and supplementing the shroud's retainment function with minimal parts and minimal wire connections. In addition, arc displacement is minimized, leading to higher lumen maintenance and longer lifetimes.
Joseph M Woods IV MD 275 Collier Rd NW STE 200, Atlanta, GA 30309 (404)2924223 (phone), (404)2925576 (fax)
Education:
Medical School Temple University School of Medicine Graduated: 1985
Procedures:
Breast Reconstruction Breast Reduction
Languages:
English
Description:
Dr. Woods IV graduated from the Temple University School of Medicine in 1985. He works in Atlanta, GA and specializes in Plastic Surgery. Dr. Woods IV is affiliated with Dekalb Medical At North Decatur and Piedmont Atlanta Hospital.
Robins Anesthesia ServicesRobins Anesthesia Services LLC 1601 Watson Blvd, Warner Robins, GA 31093 (478)9229937 (phone)
Education:
Medical School Mercer University School of Medicine Graduated: 2001
Languages:
English
Description:
Dr. Woods graduated from the Mercer University School of Medicine in 2001. He works in Warner Robins, GA and specializes in Anesthesiology. Dr. Woods is affiliated with Houston Medical Center and Perry Hospital.
Chelsea, QuebecCentury 21 Macintyre Don't let the name fool you. Joseph is as comfortable speaking in French as he is in English. Joseph grew up in the Glebe neighbourhood of Ottawa on the corner... Don't let the name fool you. Joseph is as comfortable speaking in French as he is in English. Joseph grew up in the Glebe neighbourhood of Ottawa on the corner of Fourth and Bronson in a French Canadian family.
The third in a family of four kids, he discovered the Gatineau Hills, north of Ottawa...