International Technidyne Corporation - Piscataway, NJ Piscataway, NJ Apr 2014 to Dec 2014 Staff Scientist IIInternational Technidyne Corporation Piscataway, NJ Mar 2013 to Apr 2014 Staff Scientist IInternational Technidyne Corporation - Piscataway, NJ
Apr 2011 to Mar 2013 Scientist IIInternational Technidyne Corporation - Piscataway, NJ
Mar 2007 to Apr 2011 Scientist IInternational Technidyne Corporation - Piscataway, NJ
May 2006 to Mar 2007 QC Technologist IIInternational Technidyne Corporation - Piscataway, NJ
Sep 2004 to May 2006 QC Technologist IHarrison Research Laboratories Union, NJ Jun 2003 to Sep 2004 Laboratory TechnicianSilliker, Inc Garwood, NJ Dec 2002 to Jul 2003 Microbiology Technician
Education:
Pontifical Catholic University Ponce, PR May 2002 Bachelor of Science in Biology
Skills:
TECHNICAL SKILLS Computer competency: Windows, JDE, Microsoft Word, Microsoft Excel, Pivot Tables and Analyze-it tool. Experience with Sysmex, Stago, ACL, Coulter and HPLC instrumentation Phlebotomist skills
Maria Cristina Figueroa Vazquez Sabana Grande Municipio, PR
American Truck Leasing Orlando, FL May 2003 to Nov 2012 Receptionist/Customer Service Rep./SalesRegents Vacations & Management, Inc Kissimmee, FL 2002 to 2003 Property ManagerTempus Resorts International Kissimmee, FL 1998 to 2002 Assistant ManagerExpress Title Loan Orlando, FL 1996 to 1998 ManagerNew Age Metal Fairfield, NJ 1987 to 1996 Purchasing/Administrative AssistantAsiul Fantasy Lares, P.R., US 1982 to 1986 Manager/Owner
Education:
Passaic County Vo-Tech Wayne, NJ 1993 to 1995 Diploma
Yankee Stadium Bronx, NY Mar 2011 to Jul 2011 Food PrepCity of New York Parks and Recreation Bronx, NY Dec 2010 to Feb 2011 Seasonal Maintenance WorkerSliver Bells New York, NY Dec 2007 to Jul 2008 CashierMiddle School New York, NY Nov 2005 to Jun 2006 President Parent Teacher AssociationBooker T. Learning Center New York, NY Feb 2004 to Feb 2005 Assistant TeacherFabco Shoe Store Bronx, NY Oct 2003 to Jan 2004 Assistant SupervisorColumbia Presbyterian Childcare Center New York, NY Sep 1999 to May 2003 Assistant teacher
La Guadalupe Hospice Ponce, PR Apr 2008 to Jun 2011 Administrative AssistantAlarmex Security Systems (Company End Function) Ponce, PR Aug 2005 to Mar 2008 Payroll AssistantDr. Pila Hospital Ponce, PR Jan 2005 to Dec 2005 Finance and Payroll CoordinatorPositronic Caribe, Inc./Computer Company Ponce, PR 1997 to 2003 Payroll Specialist/Human Resources Clerk
Gregory M. Colella - Montclair NJ, US Henry D. Huang - Edison NJ, US Dimitri V. Shishkin - Whippany NJ, US Maria Figueroa - Elizabeth NJ, US James A. Mawhirt - Brooklyn NY, US
Assignee:
International Technidyne Corporation - Piscataway NJ
International Classification:
G01N 33/49 B01L 3/00
US Classification:
422 73, 422102
Abstract:
An apparatus for measuring blood clotting time includes a blood clot detection instrument and a cuvette for use with the blood clot detection instrument. The cuvette includes a blood sample receptor-inlet; a channel arrangement including at least one test channel for performing a blood clotting time measurement, a sampling channel having at least one surface portion that is hydrophilic, communicating with the blood sample receptor-inlet and the at least one test channel, and a waste channel having at least one surface portion that is hydrophilic, communicating with the sampling channel; and a vent opening communicating with the sampling channel. The sampling channel, the vent opening and the waste channel, coact to automatically draw a requisite volume of a blood sample deposited at the blood receptor-inlet, into the sampling channel. More specifically, air compressed within the blood clot detection instrument, the at least one test channel of the cuvette, and the section of the sampling channel extending beyond the vent opening of the cuvette, coacts with the waste channel to cause a leading edge of the blood sample drawn into the sampling channel from the blood receptor-inlet, to pull back within the sampling channel and uncover an optical sensor in of the blood clot detection instrument. The uncovering of the optical sensor activates a pump module of the blood clot detection instrument, which draws the requisite volume of the blood sample into the at least one test channel.
Cuvette-Based Apparatus For Blood Coagulation Measurement And Testing
Gregory M. Colella - Montclair NJ, US Henry D. Huang - Edison NJ, US Dimitri Shishkin - Whippany NJ, US Maria Figueroa - Elizabeth NJ, US James A. Mawhirt - Brooklyn NY, US
Assignee:
INTERNATIONAL TECHNIDYNE CORPORATION - Piscataway NJ
International Classification:
G01N 33/49 B01L 3/00
US Classification:
422501, 422 73
Abstract:
An apparatus for measuring blood clotting time includes a blood clot detection instrument and a cuvette for use with the blood clot detection instrument. The cuvette includes a blood sample receptor-inlet; a channel arrangement including at least one test channel for performing a blood clotting time measurement, a sampling channel having at least one surface portion that is hydrophilic, communicating with the blood sample receptor-inlet and the at least one test channel, and a waste channel having at least one surface portion that is hydrophilic, communicating with the sampling channel; and a vent opening communicating with the sampling channel. The sampling channel, the vent opening and the waste channel, coact to automatically draw a requisite volume of a blood sample deposited at the blood receptor-inlet, into the sampling channel.
Cuvette-Based Apparatus For Blood Coagulation Measurement And Testing
- Bedford MA, US Henry D. Huang - Edison NJ, US Dimitri Shishkin - Whippany NJ, US Maria Figueroa - Elizabeth NJ, US James A. Mawhirt - Brooklyn NY, US
Assignee:
Instrumentation Laboratory Company - Bedford MA
International Classification:
G01N 33/49 B01L 3/00
Abstract:
An apparatus for measuring blood clotting time includes a blood clot detection instrument and a cuvette for use with the blood clot detection instrument. The cuvette includes a blood sample receptor-inlet; a channel arrangement including at least one test channel for performing a blood clotting time measurement, a sampling channel having at least one surface portion that is hydrophilic, communicating with the blood sample receptor-inlet and the at least one test channel, and a waste channel having at least one surface portion that is hydrophilic, communicating with the sampling channel; and a vent opening communicating with the sampling channel. The sampling channel, the vent opening and the waste channel, coact to automatically draw a requisite volume of a blood sample deposited at the blood receptor-inlet, into the sampling channel. More specifically, air compressed within the blood clot detection instrument, the at least one test channel of the cuvette, and the section of the sampling channel extending beyond the vent opening of the cuvette, coacts with the waste channel to cause a leading edge of the blood sample drawn into the sampling channel from the blood receptor-inlet, to pull back within the sampling channel and uncover an optical sensor in of the blood clot detection instrument. The uncovering of the optical sensor activates a pump module of the blood clot detection instrument, which draws the requisite volume of the blood sample into the at least one test channel.
Cuvette-Based Apparatus For Blood Coagulation Measurement And Testing
- Piscataway NJ, US Henry D. Huang - Edison NJ, US Anthony F. Kuklo - Bridgewater NJ, US Dimitri Shishkin - Whippany NJ, US Maria Figueroa - Elizabeth NJ, US James A. Mawhirt - Brooklyn NY, US
Assignee:
International Technidyne Corporation - Piscataway NJ
International Classification:
G01N 33/49
US Classification:
422 73, 422501
Abstract:
An apparatus for measuring blood clotting time includes a blood clot detection instrument and a cuvette for use with the blood clot detection instrument. The cuvette includes a blood sample receptor-inlet; a channel arrangement including at least one test channel for performing a blood clotting time measurement, a sampling channel having at least one surface portion that is hydrophilic, communicating with the blood sample receptor-inlet and the at least one test channel, and a waste channel having at least one surface portion that is hydrophilic, communicating with the sampling channel; and a vent opening communicating with the sampling channel. The sampling channel, the vent opening and the waste channel, coact to automatically draw a requisite volume of a blood sample deposited at the blood receptor-inlet, into the sampling channel.
Maria Gracia Figueroa " María Gracia Figueroa ", is a Peruvian model and a pageant titleholder who won Miss Earth Peru 2011 and Miss Teen Peru Universe 2009.